  • FW821 | Maple Armor

    FW821 FIRE ALARM I/O MODULE The input-output module FW821 is a UL / ULC listed device according to UL864 and ULC-S527 for fire protection signaling systems for indoor use. VIEW DATASHEET FIRE ALARM I/O MODULE The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. The output line is monitored for open lines, short-circuit faults, ground faults, and external 24VDC power source loss. Capabilities The FW821 input-output module provides one 24VDC output and one feedback input monitor. Compliance UL864 / ULC S527 / FM Listed Addressable The FW821 is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Useful to confirm a retroactive action Internal electronic address Compatible with EOLR 10K Ohms (FW421) White surface box available as an option (FW800/801) Status LED indicator

  • FW831 | Maple Armor

    FW831 RELAY MODULE The FW831 is an addressable relay module that provides two control relay outputs which will be activated simultaneously. The active status of the relay output is indicated by flashing red LED. VIEW DATASHEET FIRE ALARM RELAY MODULE The FW831 is an addressable module and takes one address on the addressable loop (ALU) of the fire alarm control panel. It is a UL listed product according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use. Relays are form-C with all contacts accessible. Capabilities The relay alarm module FW831 provides two control relay outputs which will be activated simultaneously. When the outputs are activated, the device LED will indicate the event condition by fast blinking. Compliance UL864 / ULC S527 Output Configurations It supports both normally closed and normally open output contact configurations. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 The relay model contact Rating: 30VDC 2A, 0.35pf Operating Temperature: 32°F to 120°F (0°C to 49°C) Operating Humidity: 0% to 93% RH Voltage Range: 15 to 28VDC Mounting: FW800 Base

  • 6-FM-12 12V12Ah | Maple Armor

    6-FM-12 12V12Ah ​ ​ VIEW DATASHEET ​ ​ ​ ​ ​ ​ ​ ​ MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718

  • FW972MN | Maple Armor

    FW972MN MINI HORN WITHOUT SILENCE BUTTON The FW972M-N Mini Horn is a conventional audible signal appliances that operate on Maple Armor Technologies’ NAC, listed according to UL 464 and ULC-S525 for indoor use. VIEW DATASHEET MINI HORN DEVICE The FW972M is a mini horn, small but powerful! Its low power consumption and the different settings available allow this sound device to fit a wide variety of applications. Capabilities The horns offer three sound level settings. No silence button is included with the FW972M-N. Compliance UL/ULC/FM/FCC listed Two Unique Models Designed for indoor installations, the FW972M comes with or without a silence button. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 When the polarity of the NAC circuit is switched from supervision to alarm activation, the device sounds with Temporal 3-3-3 code. Wall Mounting

  • FW6000-B12550 | Maple Armor

    FW6000-B12550 ​ ​ VIEW DATASHEET ​ ​ ​ ​ ​ ​ ​ ​ MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718

  • FW722 | Maple Armor

    FW722 MANUAL PULL STATION The FW722 addressable manual station is a UL/ULC listed device according to UL38 and ULC-S528 for Fire Protective Signaling Systems for indoor use. VIEW DATASHEET ADDRESSABLE MANUAL PULL STATION The FW722 is a Manual Station used as part of our Fire Protective Signaling Systems for indoor use. It is a normally open initiating device made from durable materials for long lasting performance. Capabilities We designed the FW722 to not only function well under pressure, but its sleek and minimalist design will give a more modern look inside your building. Compliance UL38/ULC S528 Americans with Disabilities Act The unit adheres to ADA requirements. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Addressable Manual Pull Station LED Indicator when activated Features a Reset Key Simple Push plate activation Wall Mounting

  • MODULES | Maple Armor

    FIRE ALARM MODULES Maple Armor provides you with a wide range of easy-to-use fire alarm modules. Our fire alarm modules are FM, UL, and ULC listed devices for fire protection and fire signaling systems. ABOUT OUR PRODUCTS Maple Armor provides you with nothing but reliable, robust and cost-effective fire alarm devices. All our equipment is UL, ULC, FCC listed as well as FM approved and conform to the highest standards of life safety and property loss prevention. LEARN MORE FW859 SYNC MODULE Sync Module is a device designed with FW961/FW971/FW981 Horn and/or Strobe Built-in synchronization circuit to synchronize multiple FW961s in a complete fire alarm system Up to 64 Notification Appliance Circuits (NAC), networked, stand alone or interfacing with the FW951 LEARN MORE FW951 IN-SUITE ISOLATOR MODULE Up to two Class A/B outputs Supervised and isolated outputs 200ma per output White surface box available as an option (FW800/801) No LED indicator LEARN MORE FW851 ISOLATOR MODULE The isolation module isolates the short point on the signaling line circuit (SLC) The internal relay will be triggered to cut down the line power where the short trouble is detected LEARN MORE FW841 CONV. ZONE MODULE 2-wire CLASS A/B conventional detectors Counts for 35 unit loads White surface box available as an option (FW800/801) Status LED indicator It is a UL listed product according to UL864 and ULC-S527 LEARN MORE FW831 RELAY MODULE UL / ULC listed product according to UL864 and ULC-S527 for fire protective signaling systems for indoor use Provides two control relay outputs which will be activated simultaneously LEARN MORE FW821 I/O MODULE Input-Output module UL / ULC listed device according to UL864 and ULC-S527 for fire protective signaling systems for indoor use Provides one 24VDC output and in addition monitoring for one feedback input contact LEARN MORE FW812 DUAL INPUT MODULE Internal electronic address Compatible with EOLR 10K Ohms (FW421) White Surface box available as an option (FW800/801) 4 types of input contact 2 Status LED indicators Supports two Class B input circuits LEARN MORE FW811M MINI-INPUT MODULE Input module that monitors a single dry contact UL/ULC listed device according to UL864 and ULC-S527 for fire protective signaling systems for indoor use The field circuit is monitored for open line faults and ground faults and the contact must be wired with an end of line resistor LEARN MORE FW811 INPUT MODULE Input module that monitors a single dry contact UL/ULC listed device according to UL864 and ULCS527 for fire protective signaling systems for indoor use The field circuit is monitored for open line faults and ground faults and the contact must be wired with an end of line resistor LEARN MORE FW435 MODULE BOX 2 mounting plates on hinges Accommodates up to 8 regular modules per box Accommodates up to 32 mini modules per box Integrated flange for semi-flush installation LEARN MORE FW434 MODULE BOX 2 mounting plates on hinges Accommodates up to 16 regular modules per box Accommodates up to 64 mini modules per box Integrated flange for semi-flush installation LEARN MORE

  • FW562 | Maple Armor

    FW562 ADDRESSABLE DUCT DETECTOR The FW562 is a Photoelectric duct smoke detector designed to provide early detection of smoke and/or the presence of combustion products in ventilation systems. VIEW DATASHEET PHOTOELECTRIC SMOKE DETECTOR The FW562C detector operates at temperatures from 0ºC to 49ºC (32ºF to 120ºF), can stand relative humidity levels of 0 to 93% and support 300 to 4000 ft/min of air velocity. Capabilities [Offical Web Error] Compliance FW562-A/B/C are UL-listed devices according to UL 268A, and FW562C-A/B/C are ULC listed according to ULC-S529 for fire protection systems. Addressable Equipped with a photoelectric smoke detector, the units will signal the presence of a dangerous amount of combustion product in the ventilation system. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Voltage Range: 17.6 to 28VDC Compatible with Maple Armor Technologies’ control panel model FW106, FW106C, FW106S, FW106SC. Operating Temperature: 32°F to 100°F (0°C to 38°C) Operating Humidity: 0% to 93% RH Mounting Location: Side and Top

  • 6-FM-5 12V5Ah | Maple Armor

    6-FM-5 12V5Ah ​ ​ VIEW DATASHEET ​ ​ ​ ​ ​ ​ ​ ​ MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718

  • FW6000-B650 | Maple Armor

    FW6000-B650 ​ ​ VIEW DATASHEET ​ ​ ​ ​ ​ ​ ​ ​ MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718

  • FW105 | Maple Armor

    FW105 ADDRESSABLE FIRE ALARM PANEL The FW105 Addressable Fire Alarm Panel features a compact design wide enough to fit between 16″ studs. It has a 7″ color LCD sequential screen that can display up to 8 active zones simultaneously. VIEW DATASHEET FIRE ALARM PANEL The FW105 features one addressable loop circuit (SLC) with 252 addressable devices/points as well as 6 auxiliary function buttons and 12 LED indicators. FW105 (EXTERIOR) FW105 (INTERIOR) Built-In 30 LED buttons annunciator SD-105 TRIM RING (OPTIONAL) Single flush trim for flush-mount installation Capabilities Network supports up to 32 panels (Class X) or 109 remote annunciators or panels (Class B) Compliance UL/ULC Listed Built-In Annunciator Built-in 30 LED/buttons annunciator MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Datasheet Installation Manual Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 10A power dedicate for signaling circuits Comes with 4 NAC that can be expanded to 8 NAC; 2 Amp per circuit 2 RS232, 1 USB, and 1 RJ45 port on the panel 4 Optional SLC isolator circuits available (Expandable to 8 isolators Class B)

  • FW811M | Maple Armor

    FW811M FIRE ALARM MINI-INPUT MODULE The Mini input module FW811M monitors a single dry contact and is a UL/ULC listed device according to UL864 and ULC-S527 for fire protective signaling systems for indoor use. VIEW DATASHEET FIRE ALARM INPUT MODULE It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. Capabilities The FW811M Input Module is designed to be inserted into a single gang utility box next to the dry contact device that it is monitoring. Compliance UL864 / ULC S527 Alarm Causing An alarm causing input will produce an ALARM event. The remote red LED will indicate the alarm condition by turning on steady. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Compatible with 10K Ohms end of line resistor (FW421) Compatible with FW561-RI remote LED indicator