77 items found for ""
- FW982G | Maple Armor
FW982G MULTI CANDELA STROBE The FW982 strobe produces a flash rate of one flash per second over the Regulated Voltage Range. It offers superior performance, including low power consumption and long operating life. VIEW DATASHEET MULTI-CANDELA STROBE The FW982 Fire Alarm Strobe is part of a family of multi-candela visual and/or audible signal appliances with light sources generated from white Light Emitting Diodes (LEDs), listed according to UL 1971, UL 1638, UL 464, ULC-S525, and ULC-S526 for indoor use. Capabilities The LED light source in this fire alarm strobe offers superior performance, including low power consumption and long operating life. Compliance UL/ULC Listed Output Five levels of light output are selectable. The default setting is highest level. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 The strobe alarm is equipped with a function to synchronize multiple strobes within a complete fire alarm system. Wall or Ceiling Mounting
- FW983AG | Maple Armor
FW983AG ADDRESSABLE MULTI CANDELA STROBE DEVICE Maple Armor strobe appliances produce a flash rate of one flash per second over the Regulated Voltage Range. VIEW DATASHEET ADDRESSABLE STROBE The FW983AG Fire Alarm Strobe is part of a family of addressable multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526 for indoor use. Capabilities Each Fire alarm Strobe has the intelligence to report its location (the device address) and status to the FireWatcher series fire alarm control panels. Compliance UL/ULC/FM/FCC Listed Output Six levels of light output are selectable. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 The LED light source in the strobe offers superior performance, including low power consumption and long operating life. The signaling device has the feature that can synchronize multiple horns and/or strobes in a complete fire alarm system. Wall or Ceiling Mounting
- FW851 | Maple Armor
FW851 FIRE ALARM ISOLATION MODULE The FW851 isolator module isolates the short circuit point on the addressable loop (ALU). The internal relay will be triggered to cut down the line power where the short trouble is detected. VIEW DATASHEET ISOLATION MODULE The FW851 is a UL listed product according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use. Capabilities The FW851 does not occupy an address on the Fire Alarm Control Panel’s ALU. Compliance UL864 / ULC S527 / FM Listed LED Indicator The device LED will indicate the trouble condition by yellow steady on. When the trouble is cleared, the internal relay will restore the power line and the device’s LED will indicate normal operation. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 Voltage Range: 15 to 28VDC Operating Temperature: 32°F to 120°F (0°C to 49°C) Operating Humidity: 0% to 93% RH Mounting: FW800 Base
- FW811M | Maple Armor
FW811M FIRE ALARM MINI-INPUT MODULE The Mini input module FW811M monitors a single dry contact and is a UL/ULC listed device according to UL864 and ULC-S527 for fire protective signaling systems for indoor use. VIEW DATASHEET FIRE ALARM INPUT MODULE It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. Capabilities The FW811M Input Module is designed to be inserted into a single gang utility box next to the dry contact device that it is monitoring. Compliance UL864 / ULC S527 Alarm Causing An alarm causing input will produce an ALARM event. The remote red LED will indicate the alarm condition by turning on steady. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 Compatible with 10K Ohms end of line resistor (FW421) Compatible with FW561-RI remote LED indicator
- FW972M | Maple Armor
FW972M MINI HORN DEVICE The FW972M Mini Horn is a conventional audible signal appliances that operate on Maple Armor Technologies’ NAC, listed according to UL 464 and ULC-S525 for indoor use. VIEW DATASHEET MINI HORN DEVICE The FW972M is a mini horn, small but powerful! Its low power consumption and the different settings available allow this sound device to fit a wide variety of applications. Capabilities The horns offer three sound level settings. A button is contained that when pressed will allow the device to be silenced for 10 minutes before resound. Compliance UL/ULC/FM/FCC listed Two Unique Models Designed for indoor installations, the FW972M comes with or without a silence button. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 When the polarity of the NAC circuit is switched from supervision to alarm activation, the device sounds with Temporal 3-3-3 code. Wall Mounting
- FW131 | Maple Armor
FW131 ADDRESSABLE NAC BOOSTER The new FW131 Booster Power Supply comes in a compact design for faster and easier installation. It has a user friendly interface featuring a LCD screen, 5 function keys and 4 LED indicators! VIEW DATASHEET NAC BOOSTER SUPPLY The FW131 adds 8 Class A or B signaling circuits with a max of 3A per NAC circuit. It features a striking compact design narrow enough to feet in between standard 16″ studs. Capabilities 12A Compact Switching power supply 110 – 120 VAC 60Hz, or 220 – 240 VAC 50Hz Compliance UL/ULC listed Connectivity 2 ways to connect between panels and NAC Boosters – via SLC and Pass Through MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 10A power dedicate to signaling circuits 1A Auxiliary power output 4 form C dry relay contacts
- FW435 | Maple Armor
FW435 FIRE ALARM MODULE BOX The FW435 is a module box that allows the installation of multiple Maple Armor modules into one cabinet. The FW435 can fit up to 8 modules or 16 mini modules. It integrates an external door, two mounting plates, and a backbox. VIEW DATASHEET FIRE ALARM MODULE BOX The FW435 meets the UL864 10th Edition Listed standard and the ULC-S527 4th Edition Listed standard and the ULC-5527 4th Edition Listed standard. Installation The cabinet must be fastened securely to a clean, dry, shock-free, and vibration-free surface in a protected environment. Compliance UL864 / ULC-S527 Installation The products must be installed in accordance with NFPA 72 and/or CAN/ULCS524, depending on the country of installation. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 Weight: 21.6 lb / 9.8 kg Size (mm): 381 (W) × 114 (H) × 355.6 (D) Size (in): 13’’ 9/16 (W) × 12’’ 9/16 (H) × 3’’ 15/16 (D) Screw Type: #6-32
- 3-FM-5 6V5Ah | Maple Armor
3-FM-5 6V5Ah VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- FW6000-B6120 | Maple Armor
FW6000-B6120 VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- MA1100 | Maple Armor
MA1100 WEATHERPROOF ANNUNCIATOR ENCLOSURE The weatherproof annunciator enclosure MA1100 is supplied with a heating element used for outdoor applications. VIEW DATASHEET WEATHERPROOF ENCLOSURE The MA1100 surface wall box is designed to be used with the FW123 and FW129 annunciators. The wall box is resistant to temperatures ranging from -40 to 49° C. Capabilities The FW122 LCD annunciator can be used with the enclosure. Up to 109 annunciators can be addressed by the communication circuit. Compliance UL/ULC listed Power Usage It can be used with one 20W (24VAC/VDC) heating option that activates at 1° C and deactivate 17° C. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 Lockable cabinet (Key) Front protective glass Auto-control heating system CSA SPE-1000 Approval CAN/ULC-S527 Approval
- FW6000-B12180 | Maple Armor
FW6000-B12180 VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- FW951 | Maple Armor
FW951 FIRE ALARM SYNC MODULE The FW951 Sync Module is a device designed to provide synchronization for FW962 / FW971 / FW982 / FW972M Horn and/or Strobe devices when these devices are used with a conventional non-synchronized 24 VDC NAC circuit. VIEW DATASHEET FIRE ALARM SYNC MODULE The FW951 supports one notification circuit and allows Maple Armor devices to be easily used in retrofit applications. Capabilities Allows FW962 / FW971 / FW972M / FW982 to be synchronized when connected to OEM notification circuit. There are up-to 64 Notification Appliance Circuits (NAC), networked, stand alone or interfacing with the FW951. Compliance UL864 / ULC S527 Circuits It supports up to 2 notification circuits. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmor.com Phone: +1 (888) 257-7718 Operating Voltage: 16 – 33VDC Operating Temperature: 0° – 49°C (32° – 120°F) Wire Size 12 – 18AWG Operating Humidity: 0 – 93% RH Location Indoor use only